1.
Dtsch Med Wochenschr ; 148(8): 475-482, 2023 Apr.
Artigo em Inglês, Alemão | MEDLINE | ID: covidwho-2266864

RESUMO

In case of hypoxemia, the oxygen content is often still in the lower normal range, so that there is no hypoxia in the tissue. If the hypoxia-threshold is reached in the tissue in hypoxic, anemic and also cardiac-related hypoxemia, identical counterregulations occur in the cell metabolism, regardless of the cause of hypoxemia. In clinical practice, this pathophysiologic fact is sometimes ignored, although depending on the cause of hypoxemia, assessment and therapy vary widely. While restrictive and generally accepted rules are specified in the transfusion guidelines for anemic hypoxemia, in the case of hypoxic hypoxia, the indication for invasive ventilation is made very early. The clinical assessment and indication are limited to the parameters oxygen saturation, oxygen partial pressure and oxygenation index. During the corona pandemic, misinterpretations of pathophysiology have become evident and may have led to unnecessary intubations. However, there is no evidence for the treatment of hypoxic hypoxia with ventilation. This review addresses the pathophysiology of the different types of hypoxia focusing on the problems associated with intubation and ventilation in the intensive care unit.


Assuntos
Anemia , Hipóxia , Humanos , Hipóxia/etiologia , Hipóxia/terapia , Anemia/terapia , Anemia/complicações , Pulmão , Unidades de Terapia Intensiva , Oxigênio/uso terapêutico
2.
Pneumologie ; 76(4): 260-271, 2022 Apr.
Artigo em Alemão | MEDLINE | ID: covidwho-1805704

RESUMO

Inhalation therapy is a cornerstone especially in pulmonary diseases or comorbidities, either in invasive or noninvasive mechanical ventilation. In pediatric patients, mainly in respiratory failure of the premature born child inhalation of surfactant is crucial in the therapy. Additional drugs given by inhalation are antibiotics, mucoactive substances and drugs that treat pulmonary hypertension. This article describes main deposition mechanisms of inhalation therapies and presents recommendations for correct performance of inhalation therapy in invasively as well as noninvasively ventilated patients in ICU. Also safety aspects for patients and medical staff during aerosol therapy in the Corona pandemic era are discussed.


Assuntos
Unidades de Terapia Intensiva , Respiração Artificial , Administração por Inalação , Aerossóis , Criança , Humanos , Terapia Respiratória
3.
J Occup Environ Hyg ; 18(3): 118-127, 2021 03.
Artigo em Inglês | MEDLINE | ID: covidwho-1066172

RESUMO

During the beginning of the SARS-CoV-2 pandemic, there was a shortage of masks and respirators for the protection of health care professionals. Masks for noninvasive ventilation (NIV) in combination with viral-proof filters, worn by healthcare workers, could serve as an alternative protection measure. We determined the simulated protection factor (SPF) of such devices in comparison to conventional surgical masks, N95, and FFP3 respirators. Masks and respirators were mounted on a ventilated mannequin head in a test-chamber. Isotonic saline containing 150 MBq 99mTC-DTPA (99mTc-diethylenetriamine pentaacetate (DTPA) was nebulized inside the box. The aerosol had a mass median aerodynamic diameter of 0.6 ± 0.4 µm. SPFs were measured using radioactive DTPA particles in the mannequin test system by calculating the ratio of unfiltered particles (Pu) and filtered particles (Pf) for each tested device (SPF = Pu/Pf). Simulated protection factors were 15.6 ± 3.6 for a ResMed AcuCare mask plus filter, 3.5 ± 0.2 for a ResMed Mirage Quattro FX mask plus filter, 9.5 ± 0.8 for a Loewenstein JOYCEclinc FF mask plus filter, 1.9 ± 0.2 for a surgical mask with a rubber band, 2.7 ± 0.7 for a surgical mask with ribbons, 2.3 ± 0.3 for an FFP3 respirator, and 3.6 ± 1.3 for an N95 respirator. The ResMed AcuCare and the Loewenstein JOYCEclinic FF mask were more effective than any other of the tested devices (p < 0.001). In conclusion, masks normally used for NIV with viral-proof filters can effectively filter respirable particles.


Assuntos
COVID-19/prevenção & controle , Máscaras , Dispositivos de Proteção Respiratória , Filtração/instrumentação , Manequins , Respiradores N95 , Ventilação não Invasiva/instrumentação , Exposição Ocupacional/prevenção & controle , SARS-CoV-2 , Pentetato de Tecnécio Tc 99m
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA